Uvod
This manual provides essential instructions for the safe installation, operation, and maintenance of your APC AP7922 32A 230V Switched Rack PDU. The AP7922 is a rack-mountable power distribution unit designed to provide advanced power control and monitoring capabilities for IT equipment in data centers and server rooms. It features AC 230V input, Ethernet 10/100 connectivity, and 16 output connectors, all within a 2U, 19-inch form factor.
Važne sigurnosne informacije
Please read and understand all safety instructions before installing or operating this equipment. Failure to follow these instructions could result in electric shock, fire, or serious injury.
- Ovaj uređaj je namijenjen samo za unutarnju upotrebu.
- Connect the PDU to a properly grounded power source.
- Do not attempt to open or service the PDU. Refer all servicing to qualified personnel.
- Ensure the total current draw of connected equipment does not exceed the PDU's maximum current rating (32 Amps).
- Isključite napajanje prije izvođenja bilo kakvih postupaka održavanja ili instalacije.
Sadržaj paketa
Prilikom raspakiranja provjerite jesu li svi predmeti prisutni:
- APC AP7922 Switched Rack PDU
- Vodič za instalaciju
- Nosači za montažu na stalak
- Serial configuration cable
- CD s dokumentacijom
Značajke proizvoda
The APC AP7922 Switched Rack PDU offers the following key features:
- Preklopne utičnice: Remotely control power to individual outlets for power cycling, delayed sequencing, and load shedding.
- Upravljanje mrežom: Full-featured network management interface via Ethernet 10/100 for remote monitoring and control.
- Trenutno praćenje: Monitor the aggregate current draw per PDU to prevent circuit overloads.
- Dizajn koji se može montirati u stalak: Occupies 2U of rack space, compatible with standard 19-inch racks.
- Izlazni priključci: Equipped with 16 C13 output connectors.
- Ulazni voltage: Supports AC 230V input.

Slika: prednja strana view of the APC AP7922 Switched Rack PDU, showing the 16 C13 outlets and network interface.
Upute za postavljanje
1. Montaža na stalak
- Identify two available 2U spaces in your standard 19-inch equipment rack.
- Attach the provided rack-mounting brackets to the PDU using the screws supplied.
- Secure the PDU into the rack using appropriate rack screws. Ensure it is firmly seated and level.
2. Priključak za napajanje
- Connect the PDU's input power cord to a dedicated 230V, 32A power source. Ensure the power source is properly grounded.
- Do not overload the circuit. Verify that the total load of connected devices will not exceed 32 Amps.
3. Mrežna veza
- Connect a standard Ethernet cable from the PDU's network port to your network switch or router.
- The PDU will obtain an IP address via DHCP by default. Refer to the full user manual for static IP configuration.
Upute za rad
Powering On/Off Connected Devices
Once the PDU is powered and connected to the network, you can manage its outlets remotely.
- Access the PDU's web sučelja unosom njegove IP adrese u a web preglednik.
- Log in using the default credentials (refer to the full manual for details).
- Navigate to the outlet control section. From here, you can individually switch on, switch off, or cycle power to each of the 16 C13 outlets.
Monitoring Current Draw
The web interface also provides real-time monitoring of the aggregate current draw. This allows you to ensure that the PDU and its connected circuit are not overloaded.
Održavanje
- Čišćenje: Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents.
- Ažuriranja firmvera: Provjerite APC website for available firmware updates to ensure optimal performance and security. Follow the instructions provided with the firmware package for safe updating.
- Uprava za kabele: Ensure all power and network cables are neatly routed and secured to prevent accidental disconnections or damage.
Rješavanje problema
| Problem | Mogući uzrok | Otopina |
|---|---|---|
| PDU does not power on. | Nema ulaznog napajanja; isključen je osigurač. | Verify the power cord is securely connected. Check the building's circuit breaker for the PDU's power source. |
| Nije moguće pristupiti web sučelje. | Incorrect IP address; network connectivity issue; PDU not powered. | Ensure the PDU is powered on. Verify network cable connection. Confirm the correct IP address. Check network settings. |
| Outlets do not switch. | Software issue; PDU fault. | Try restarting the PDU. If the issue persists, contact technical support. |
| Alarm za preopterećenje. | Total current draw exceeds PDU rating. | Disconnect non-essential equipment to reduce the load. Redistribute equipment across multiple PDUs if necessary. |
Tehničke specifikacije
| Značajka | Detalj |
|---|---|
| Broj modela | AP7922 |
| Marka | APC tvrtke Schneider Electric |
| Form Factor | 2U Rack-mountable, 19-inch |
| Ulazni voltage | 230 V AC |
| Ulazna struja | 32 Amps |
| Izlazni voltage | 230 V AC |
| Izlazna struja | 32 Amps (maks.) |
| Broj utičnica | 16 |
| Vrsta konektora | C13 |
| Mrežno sučelje | Ethernet 10/100 |
| Wattage | 7360 vata |
| Dimenzije (V x Š x D) | 4.49 x 17.52 x 3.5 inča |
| Težina | 0.7 kilogram |
| Materijal | Metal |
| Boja | Crna |
Jamstvo i podrška
Informacije o jamstvu
APC proizvodi obično dolaze sa standardnim jamstvom proizvođača. Molimo pogledajte jamstveni list koji je priložen uz vaš proizvod ili posjetite službenu APC stranicu. website for detailed warranty terms and conditions specific to the AP7922 model.
Tehnička podrška
For technical assistance, troubleshooting, or to report issues, please contact APC customer support. You can find contact information and additional resources on the official Schneider Electric webstranica:
Službeni predstavnik tvrtke APC tvrtke Schneider Electric Webmjesto