This manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton 15 Amp, 125 Volt, Tamper-Resistant Duplex Receptacle (Model 25249-TFB). This commercial-grade, self-grounding receptacle features a straight blade design and a brass finish, engineered for demanding environments such as hotels, schools, hospitals, and commercial office buildings. It is designed to withstand rigorous use and offers enhanced safety features.

Sigurnosne informacije

UPOZORENJE: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

Prijedlog 65 Upozorenje: Ovaj proizvod može sadržavati kemikalije za koje je državi Kaliforniji poznato da uzrokuju rak i urođene mane ili druge reproduktivne štete. Operite ruke nakon rukovanja.

  • Do not use this device with aluminum wiring. Use only with copper or copper-clad wire.
  • Provjerite jesu li svi spojevi čvrsti i sigurni kako biste spriječili pregrijavanje.
  • This receptacle is tamper-resistant, designed to prevent insertion of foreign objects into the receptacle openings.
  • Ne prekoračujte navedene električne nazivne vrijednosti od 15 Ampi 125 volti.

Značajke proizvoda

  • TampDizajn otporan na er: Meets NEC 2020 article 406.12, providing enhanced safety by preventing the insertion of single objects into the receptacle openings.
  • Komercijalni stupanj: Built to withstand demanding environments, ensuring durability and long-term performance.
  • Samouzemljenje: Features an integral self-grounding clip for quick and easy installation into a properly grounded metal box.
  • Izdržljiva konstrukcija: Thermoplastic receptacle face and body resist breakage.
  • Ready-To-Wire Unit: All-in-one design facilitates quick and easy installation.
Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish

Image: Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish. This image shows the front view of the receptacle with its brass faceplate and two tamputičnice otporne na er.

Postavljanje i instalacija

Installation of electrical devices should only be performed by qualified personnel. Always ensure power is disconnected before beginning any work.

  1. Isključite napajanje: Locate the circuit breaker or fuse that supplies power to the outlet where the receptacle will be installed. Turn it off and verify that power is off using a voltage tester.
  2. Uklonite staru utičnicu (ako je primjenjivo): Carefully remove the existing wall plate and receptacle from the electrical box. Disconnect the wires, noting their connections (hot, neutral, ground).
  3. Pripremite žice: Strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires. Ensure wires are straight.
  4. Spojite žice:
    • Spojite hot (black) wire to the brass-colored screw terminal.
    • Spojite neutralno (bijelo) wire to the silver-colored screw terminal.
    • Spojite tlo (zeleni ili goli bakar) wire to the green screw terminal. This receptacle is self-grounding, meaning it will ground itself to a properly grounded metal box via its mounting strap.
    Provjerite jesu li svi spojevi žica čvrsti i sigurni.
  5. Priključak za montažu: Carefully fold the wires into the electrical box, then insert the new receptacle and secure it with the mounting screws provided.
  6. Postavite zidnu ploču: Attach the decorative wall plate (sold separately) over the receptacle.
  7. Vrati snagu: Ponovno uključite napajanje na prekidaču ili kutiji s osiguračima.
  8. Test: Test the receptacle with a known working appliance or receptacle tester to ensure proper function.
Leviton 25249-TFB Receptacle Back View

Slika: Stražnja strana view of the Leviton 25249-TFB receptacle, showing the screw terminals for wiring connections (hot, neutral, ground).

Upute za rad

The Leviton 25249-TFB Tamper-Resistant Duplex Receptacle operates like a standard electrical outlet, with added safety features.

  • Priključivanje: Insert the plug of your appliance or device firmly into one of the two receptacle openings. The tamper-resistant shutters may require slightly more force to open than a traditional receptacle. Ensure both prongs are inserted simultaneously and evenly.
  • Isključivanje: Grasp the plug and pull it straight out from the receptacle. Do not pull by the cord.
  • Nosivost: Do not overload the receptacle. The total current drawn by all connected devices should not exceed 15 Amps.

Održavanje

The Leviton 25249-TFB receptacle requires minimal maintenance.

  • Čišćenje: To clean the receptacle face, ensure power is off at the circuit breaker. Use a soft, damp tkanina. Nemojte koristiti abrazivna sredstva za čišćenje ili otapala.
  • Inspekcija: Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power and have the receptacle inspected and replaced by a qualified electrician.
  • Razmatranja okoliša: While durable, avoid exposing the receptacle to excessive moisture or extreme temperatures beyond its operational specifications.

Rješavanje problema

ProblemMogući uzrokOtopina
Nema struje na utičnici.Circuit breaker tripped or fuse blown. Loose wiring connection.Check and reset the circuit breaker or replace the fuse. If problem persists, turn off power and check wiring connections. Consult an electrician if necessary.
Plug does not insert easily.Tamper-resistant shutters are engaged.Ensure both prongs of the plug are aligned and inserted simultaneously and firmly. Do not force the plug.
Posuda je topla na dodir.Overloaded circuit. Loose wiring connection.Unplug some devices to reduce load. Turn off power and check wiring connections. If warmth persists, consult an electrician immediately.

Tehnički podaci

  • Model: 25249-TFB
  • Ampdoba: 15 Amps
  • Voltage: 125 volti
  • Konfiguracija: 5-15R
  • Broj polova: 2
  • Broj žica: 3
  • Uzemljenje: Samouzemljenje
  • Materijal: Nylon (body), Brass (finish)
  • Boja: Mjedena završna obrada
  • Standardi i certifikati: UL 498, CSA C22.2, NOM 057 Approved
  • Ukupna snaga utičnica: 2

Jamstvo i podrška

Jamstvo: This Leviton product is backed by a 10-Year Limited Warranty. For detailed warranty terms and conditions, please refer to the official Leviton webstranicu ili se obratite korisničkoj podršci.

Korisnička podrška: For technical assistance, troubleshooting, or warranty claims, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the product packaging or the Leviton webmjesto.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.