BUFFALO LSW3-GT-24NSR

BUFFALO Giga Switching Hub 24-Port LSW3-GT-24NSR User Manual

1. Uvod

The BUFFALO Giga Switching Hub LSW3-GT-24NSR is a 24-port Gigabit Ethernet switch designed for high-speed network environments. It is ideal for small to medium-sized offices and workplaces requiring robust and reliable network connectivity. This device supports full Gigabit speeds across all ports, ensuring efficient data transfer.

Key features include a fanless design for silent operation and enhanced reliability, as well as a loop detection function to prevent network disruptions caused by accidental network loops.

2. Sigurnosne informacije

Prije upotrebe uređaja pročitajte i razumite sljedeće sigurnosne mjere kako biste spriječili ozljede ili oštećenja.

  • Napajanje: Use only the provided power adapter. Ensure the power outlet meets the specified voltage zahtjevi.
  • Ventilacija: Do not block ventilation openings. Ensure adequate airflow around the device to prevent overheating.
  • Okruženje: Avoid exposing the device to water, high humidity, extreme temperatures, or direct sunlight.
  • Rukovanje: Do not drop or subject the device to strong impacts. Do not attempt to open or repair the device yourself. Refer all servicing to qualified personnel.
  • Kabeli: Ensure all network cables are properly connected and secured.

3. Sadržaj paketa

Provjerite jesu li svi artikli prisutni u paketu:

  • BUFFALO Giga Switching Hub LSW3-GT-24NSR Unit
  • Kabel za napajanje
  • Rack Mount Brackets (if included with your model)
  • Gumene nožice (za postavljanje na radnu površinu)

4. Postavljanje

4.1 Fizička instalacija

The LSW3-GT-24NSR can be installed on a desktop or mounted in a 19-inch equipment rack.

Položaj na radnoj površini:

  1. Attach the included rubber feet to the bottom of the unit to prevent slipping and provide stability.
  2. Place the unit on a flat, stable surface with adequate ventilation.

Montaža na stalak:

  1. Attach the rack mount brackets to the sides of the unit using the provided screws.
  2. Secure the unit into a standard 19-inch equipment rack using appropriate rack screws (not included).

4.2 Spajanje mrežnih kabela

Connect your network devices (computers, servers, other switches) to any of the 24 RJ-45 ports on the front panel using standard Ethernet cables (Category 5e or higher recommended for Gigabit speeds).

Ispred view of the BUFFALO LSW3-GT-24NSR Giga Switching Hub, showing 24 Ethernet ports and LED indicators.

Slika 1: Prednja ploča iznadview with 24 Ethernet Ports and Status LEDs.

4.3 Povezivanje struje

  1. Connect the power cable to the AC IN port on the rear of the device.
  2. Uključite drugi kraj kabela za napajanje u odgovarajuću utičnicu.
  3. The device will power on automatically. The POWER LED on the front panel should illuminate.
Stražnji view of the BUFFALO LSW3-GT-24NSR Giga Switching Hub, showing the AC IN power port.

Slika 2: Stražnja ploča iznadview with AC IN Power Port.

5. Upute za rad

5.1 LED indikatori

The front panel features several LED indicators to monitor the status of the switch and its ports.

Krupni plan view of the LED indicators and Loop Detection switch on the BUFFALO LSW3-GT-24NSR.

Slika 3: Detaljno view of LED Indicators and Loop Detection Switch.

Tablica 1: Status LED indikatora
Naziv LED diodeStatusOpis
VLASTOnUređaj je uključen.
VEZA / DJEL (po portu)OnA network device is connected and a link is established.
BljeskanjePodaci se prenose ili primaju putem porta.
1000/100/10M (po portu)zelenaPort is operating at 1000 Mbps (Gigabit Ethernet).
NarančastoPort is operating at 100 Mbps (Fast Ethernet).
IsključenoPort is operating at 10 Mbps (Ethernet).
LOOP DETECTOnA network loop has been detected.

5.2 Loop Detection Function

The LSW3-GT-24NSR features a hardware switch for enabling or disabling the loop detection function. This function helps prevent network instability caused by accidental network loops.

Krupni plan view of the Loop Detection switch on the BUFFALO LSW3-GT-24NSR, showing ON and OFF positions.

Figure 4: Loop Detection Switch (ON/OFF).

  • NA: Loop detection is active. If a loop is detected, the corresponding port will be automatically shut down to prevent network broadcast storms, and the LOOP DETECT LED will illuminate.
  • OFF: Loop detection is disabled.

It is recommended to keep the loop detection function ON for network stability.

6. Održavanje

6.1 Čišćenje uređaja

To maintain optimal performance, periodically clean the exterior of the switch.

  • Prije čišćenja isključite kabel za napajanje.
  • Za brisanje površine koristite meku, suhu krpu.
  • Do not use liquid cleaners, aerosols, or solvents, as these may damage the casing ili unutarnje komponente.

6.2 Razmatranja okoliša

Ensure the device is operated within its specified environmental conditions:

  • Temperatura: 0°C do 40°C (32°F do 104°F)
  • Vlažnost: 10% do 85% (bez kondenzacije)

7. Rješavanje problema

If you encounter issues with your BUFFALO Giga Switching Hub, refer to the following common problems and solutions.

7.1 Bez napajanja

  • Simptom: LED POWER je isključen.
  • Otopina: Check if the power cable is securely connected to both the device and the power outlet. Ensure the power outlet is functional.

7.2 No Link or Slow Speed on a Port

  • Simptom: The LINK/ACT LED for a connected port is off, or the 1000/100/10M LED indicates a lower speed than expected (e.g., 100M instead of 1000M).
  • Otopina:
    • Provjerite je li Ethernet kabel sigurno spojen na oba kraja.
    • Try a different Ethernet cable. Ensure it is a Category 5e or higher cable for Gigabit speeds.
    • Spojite uređaj na drugi priključak na preklopniku.
    • Check the network adapter settings on the connected device (computer, server) to ensure it is configured for auto-negotiation or the correct speed.

7.3 Network Instability / LOOP DETECT LED is On

  • Simptom: The LOOP DETECT LED is illuminated, and network performance is degraded or unstable.
  • Otopina:
    • A network loop has been detected. This typically occurs when two ports on the same switch (or different switches) are connected to each other, creating an infinite data path.
    • Carefully inspect your network cabling to identify and remove any redundant connections that form a loop.
    • If the loop detection switch is ON, the affected port will be automatically shut down. Once the loop is resolved, the port should resume normal operation.

8. Specifikacije

Tablica 2: Specifikacije proizvoda
ZnačajkaOpis
MarkaBIVOLI
Broj modelaLSW3-GT-24NSR
Broj priključaka24 x 10/100/1000BASE-T RJ-45 priključaka
Preklopni kapacitet48 Gbps (neblokirajuće)
Brzina prosljeđivanja35.7 Mpps
Veličina tablice MAC adresa8K unosa
Podrška za Jumbo FrameDo 9 KB
ZnačajkeAuto-MDI/MDIX, Auto-Negotiation, Loop Detection Function, Fanless Design
NapajanjeUnutarnje AC napajanje
Dimenzije (Š x D x V)(Specific dimensions not provided in source, typical for 1U rackmount)
Težina(Specific weight not provided in source)
Radna temperatura0°C do 40°C
Radna vlažnost10% do 85% (bez kondenzacije)

9. Jamstvo i podrška

This BUFFALO product is covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official BUFFALO webstranicu za detaljne uvjete jamstva.

For technical support, product registration, or further assistance, please visit the official BUFFALO support webweb-mjesto ili se obratite njihovoj službi za korisnike. Kontaktne podatke obično možete pronaći na proizvođačevoj webmjestu ili pakiranju proizvoda.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.