1. Uvod
This manual provides essential information for the safe and efficient operation of your Bromic Heating Smart-Heat Platinum 500 Radiant Infrared Patio Heater. This natural gas heater delivers 39,800 BTU/hour of direct heat, designed to warm outdoor living spaces effectively. Please read all instructions carefully before installation and use.

Slika 1: Prednja strana view of the Bromic Heating Smart-Heat Platinum 500 Radiant Infrared Patio Heater.
2. Važne sigurnosne informacije
UPOZORENJE: Neispravna instalacija, podešavanje, izmjena, servis ili održavanje mogu uzrokovati ozljede ili oštećenje imovine. Prije instaliranja ili servisiranja ove opreme temeljito pročitajte upute za instalaciju, rad i održavanje.
- Prilikom rada grijača osigurajte odgovarajuću ventilaciju.
- Nemojte pohranjivati niti koristiti benzin ili druge zapaljive pare i tekućine u blizini ovog ili bilo kojeg drugog uređaja.
- Držite djecu i kućne ljubimce podalje od grijača tijekom rada.
- Maintain clear distances from combustible materials as specified in the installation section.
- Ovaj proizvod sadrži kemikalije za koje je u saveznoj državi Kaliforniji poznato da uzrokuju rak i urođene mane ili druge reproduktivne štete. (Upozorenje o prijedlogu 65)
3. Značajke proizvoda
- Sleek Contemporary Styling: Features brushed stainless steel and tinted ceramic glass for an aesthetic design.
- Radiant Infrared Burner: Heats up quickly, providing direct heat to warm individuals in the area.
- Otpornost na vjetar: Designed to operate effectively in winds up to 12 miles per hour for consistent heating.
- Podesivi montažni nosač: The wall bracket houses the control system away from heat and allows the heater head to pivot 25-degrees to the left and right of center for directional heat.
- Svestrana primjena: Suitable for both residential and commercial installations.
- Automatic Reignition: Provides continuous heat and convenience.
- Izdržljiva konstrukcija: Made of stainless steel with a brushed finish.
- Electronic Ignition System: Requires 120V for operation.

Figure 2: The sleek design of the Bromic Platinum 500 heater.
4. Instalacija
Installation of the Bromic Smart-Heat Platinum 500 heater should be performed by a qualified and licensed professional in accordance with local codes and regulations.
4.1 Mogućnosti montaže
The heater offers flexible mounting options:
- Na zid: Utilize the provided mounting bracket. The bracket allows the heater to pivot 25 degrees left or right.
- Ceiling Suspended: Can be hung from the ceiling using an optional Ceiling Post Mount (not included).
The optimum mounting height is 8 feet from the floor to the bottom of the heater. If the distance above the heater is less than 42 inches, or if the heater will be exposed to elements, an accessory Heat Deflector must be used.

Slika 3: Bočna strana view illustrating the mounting bracket and design.
4.2 Priključci za plin i struju
- Connect to a natural gas supply. All gas connections must comply with local codes.
- The electronic ignition system requires a 120V electrical supply. Ensure proper grounding.
Video 1: Overview of the Bromic Platinum Gas Radiant Heater installation and features. This video demonstrates the heater's design and mounting flexibility.
5. Upute za rad
5.1 Pokretanje grijača
- Uvjerite se da je ventil za dovod plina otvoren.
- Activate the electronic ignition system (requires 120V). The heater features automatic reignition.
- Allow a few minutes for the radiant elements to reach full operating temperature.
5.2 Adjusting Heat Direction
The mounting bracket allows the heater head to pivot 25 degrees to the left or right. Carefully adjust the heater's angle to direct heat to your desired area. Ensure the heater is cool before making physical adjustments.
5.3 Isključivanje grijača
- Deactivate the electronic ignition system.
- Close the main gas supply valve if the heater will not be used for an extended period.
6. Održavanje
Regular maintenance ensures optimal performance and longevity of your heater. Always ensure the heater is completely cool and the gas supply is turned off before performing any maintenance.
- Čišćenje: Povremeno čistite vanjske površine mekom,amp tkanina. Nemojte koristiti abrazivna sredstva za čišćenje ili otapala.
- Keramičko staklo: The tinted ceramic glass should be inspected for cracks or damage. Clean gently if necessary.
- Inspekcija plamenika: Annually, have a qualified technician inspect the burner and gas connections for any blockages or wear.
- Heat Deflector: If an optional heat deflector is installed, ensure it is free from debris.
7. Rješavanje problema
If you encounter issues with your heater, refer to the following common troubleshooting steps. For complex problems, contact a qualified service technician.
7.1 Heater Not Igniting
- Check if the natural gas supply valve is fully open.
- Verify that the 120V electrical supply for the electronic ignition is active.
- Ensure there are no obstructions around the burner.
7.2 Insufficient Heat Output
- Confirm the heater is positioned correctly to direct heat to the desired area.
- Check for strong winds exceeding 12 mph, which can reduce heating effectiveness.
- Ensure the area is within the recommended heating coverage of 200 square feet.
8. Specifikacije
| Marka | Bromic Heating |
| Broj modela | BR-PLA500-NG |
| Vrsta goriva | Prirodni plin |
| BTU izlaz | 39,800 BTU/sat |
| Pokrivenost grijanjem | Do 200 četvornih stopa |
| Dimenzije proizvoda | 15.6"D x 29.75"Š x 15"V |
| Težina artikla | 40 funti |
| Voltage | 120 Volts (for electronic ignition) |
| Vrsta montaže | Wall or Ceiling (with optional accessories) |
| Posebna značajka | Energy Efficient, Wind Resistance |

Figure 4: Dimensional drawing of the heater.
9. Jamstvo i podrška
For warranty information and customer support, please refer to the documentation included with your product or visit the official Bromic Heating webmjesto. Čuvajte račun za jamstvene zahtjeve.