1. Uvod
The Inogen One G3 External Battery Charger (Model BA-303) is designed to provide a convenient and efficient method for charging Inogen One G3 standard and extended batteries independently of the Inogen One G3 portable oxygen concentrator. This manual provides essential information for the safe and effective use of your charger.

Image: The Inogen One G3 External Battery Charger with an Inogen One G3 battery inserted, ready for charging.
2. Sigurnosne informacije
Please read all safety instructions before using the Inogen One G3 External Battery Charger. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Use only with Inogen One G3 standard (BA-300) and extended (BA-316) batteries.
- Ne izlažite punjač vodi ili prekomjernoj vlazi.
- Ne pokušavajte rastaviti ili modificirati punjač.
- Ensure the charger is connected to a compatible electrical outlet (100-240V AC, 50-60Hz).
- Držite punjač dalje od izvora topline i izravne sunčeve svjetlosti.
- If the charger or power cord is damaged, discontinue use immediately and contact customer support.
Pravno odricanje od odgovornosti: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. This product is an accessory for a medical device.
3. Sadržaj paketa
Provjerite jesu li svi artikli prisutni u paketu:
- Inogen One G3 External Battery Charger (Model BA-303)
- AC ulazni kabel
4. Kompatibilnost
This external battery charger is specifically designed for use with Inogen One G3 batteries. It supports both the standard (BA-300) and extended (BA-316) Inogen One G3 battery models.

Image: An accessory compatibility chart showing the Inogen One G3 External Battery Charger (BA-303) is compatible with Inogen One G3 Standard (BA-300) and Extended (BA-316) batteries.
5. Upute za postavljanje
Follow these steps to set up your Inogen One G3 External Battery Charger:
- Spojite AC napajanje: Plug the AC input cord into an electrical outlet.

Image: Step 1 of the charging process, showing the AC power cord being plugged into a wall outlet.
- Spoji na punjač: Plug the other end of the AC input cord into the designated port on the external battery charger.

Image: Step 2 of the charging process, illustrating the AC power cord connected to the external battery charger.
- Umetnite bateriju: Slide your Inogen G3 battery onto the charger until it clicks and locks into place. Ensure it is seated correctly.

Image: Step 3 of the charging process, showing an Inogen G3 battery being slid onto the charger until it locks.
6. Upute za rad
Once the charger is set up and a battery is inserted, the charging process will begin automatically.
Indikatori punjenja
- Stalno crveno svjetlo: When the battery is correctly positioned on the charger, a solid red light will illuminate, indicating that the battery is actively charging.

Image: Step 4 of the charging process, showing the charger with a solid red light, indicating the battery is charging.
- Zeleno svjetlo: When the green light illuminates, the battery is fully charged and ready for use.

Image: Step 5 of the charging process, showing the charger with a green light, indicating the battery is fully charged.
Vremena punjenja
Approximate charging times are as follows:
- Standard Inogen One G3 Battery: Up to 5 hours
- Extended Inogen One G3 Battery: Up to 8 hours

Image: The Inogen One G3 External Battery Charger with a battery, illustrating the approximate charging times for standard and extended batteries.
For continuous use, consider having multiple batteries and an additional external charger to ensure batteries are always ready.
7. Održavanje
The Inogen One G3 External Battery Charger requires minimal maintenance.
- Keep the charger clean and free from dust. Wipe with a dry, soft cloth.
- Ne koristite tekuća sredstva za čišćenje ili abrazivne materijale.
- Čuvajte punjač na hladnom i suhom mjestu kada nije u upotrebi.
- Redovito provjeravajte kabel za napajanje ima li znakova oštećenja.
8. Rješavanje problema
Ako imate problema s punjačem, pogledajte sljedeće uobičajene probleme i rješenja:
| Problem | Mogući uzrok | Otopina |
|---|---|---|
| Charger light not illuminating | No power to charger, battery not inserted correctly, or charger malfunction. |
|
| Trepće crveno svjetlo | Error during charging process. |
|
| Baterija se ne puni do kraja | Battery issue or charger malfunction. |
|
9. Specifikacije
| Značajka | Detalj |
|---|---|
| Broj modela | BA-303 |
| Kompatibilnost | Inogen One G3 Standard (BA-300) and Extended (BA-316) Batteries |
| Ulazni voltage | 100-240V izmjenična struja, 50-60Hz |
| Izlazni voltage | 15 volti |
| Dimenzije (Š x D x V) | 3.3 in. x 2.75 in. x 1 in. |
| Težina | 0.12 lbs. (cca.) |
| Standard Battery Charge Time | Do 5 sati |
| Extended Battery Charge Time | Do 8 sati |
10. Jamstvo i podrška
For warranty information and customer support, please refer to the documentation provided with your original Inogen One G3 portable oxygen concentrator or visit the official Inogen webmjesto.
Također možete posjetiti Inogen Store on Amazon za dodatne informacije o proizvodu i priboru.