1. Uvod
This manual provides essential information for the safe and efficient operation of your GREISINGER GMH 3531 pH/Redox/Temperature Meter. Please read these instructions carefully before using the device and keep them for future reference. The GMH 3531 is designed for precise measurement of pH, Redox potential, and temperature in various applications.
2. Sigurnosne upute
- Always operate the device within the specified environmental conditions.
- Ne izlažite uređaj ekstremnim temperaturama, vlazi ili izravnoj sunčevoj svjetlosti.
- Izbjegavajte ispuštanje ili izlaganje uređaja jakim udarcima.
- Only use original accessories and probes supplied or approved by GREISINGER.
- Ne pokušavajte sami otvarati ili popravljati uređaj. Za sve servisne radove obratite se ovlaštenom osoblju.
- Držite uređaj i njegovu dodatnu opremu izvan dohvata djece.
- Baterije i uređaj odložite u skladu s lokalnim propisima.
3. Sadržaj paketa
Prilikom raspakiranja, molimo provjerite jesu li svi dolje navedeni artikli prisutni i neoštećeni:
- GREISINGER GMH 3531 pH/Redox/Temperature Meter
- Priručnik za rad
- pH electrode (if included in specific model variant)
- Temperature probe (if included in specific model variant)
- Batteries (installed or separate)

Image: The GREISINGER GMH 3531 pH/Redox/Temperature Meter, showing its compact design and display. This image illustrates the main unit of the device.
4. Postavljanje
4.1. Ugradnja baterije
- Otvorite poklopac odjeljka za baterije koji se nalazi na stražnjoj strani uređaja.
- Insert the specified batteries, ensuring correct polarity (+/-).
- Čvrsto zatvorite poklopac odjeljka za baterije.
4.2. Priključak sonde
- Connect the pH electrode to the designated BNC connector on the device. Ensure a firm connection.
- Connect the temperature probe to its dedicated input jack.
- Ensure all connections are clean and dry before use.
5. Upute za rad
5.1. Uključivanje/isključivanje
Pritisnite tipku UKLJUČENO/ISKLJUČENO button to power on the device. Press and hold the UKLJUČENO/ISKLJUČENO button for approximately 3 seconds to power off.
5.2. Kalibracija
Regular calibration is crucial for accurate measurements. Refer to the specific calibration procedure for pH and Redox measurements outlined below.
5.2.1. pH kalibracija
- Prepare fresh pH buffer solutions (e.g., pH 4.00, 7.00, 10.00).
- Rinse the pH electrode thoroughly with distilled water and blot dry.
- Immerse the electrode in the first buffer solution (e.g., pH 7.00).
- Enter calibration mode as per the device's menu.
- Follow on-screen prompts to confirm the buffer value.
- Repeat for subsequent buffer solutions.
5.2.2. Redox Calibration
Redox electrodes typically do not require calibration in the same way as pH electrodes. However, their functionality can be checked using a known Redox test solution.
5.3. Uzimanje mjerenja
- Ensure the device is calibrated.
- Rinse the probe(s) with distilled water and blot dry.
- Immerse the probe(s) into the sample solution. Ensure the sensing part of the probe is fully submerged.
- Allow the reading to stabilize on the display.
- Record the measurement.
- After measurement, rinse the probe(s) thoroughly and store according to maintenance guidelines.
6. Održavanje
6.1. Čišćenje uređaja
Wipe the device housing with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the device openings.
6.2. Probe Care and Storage
- pH elektroda: Always keep the pH electrode wet. Store it in a suitable storage solution (e.g., 3M KCl solution or pH 4 buffer). Never store in distilled water.
- Redoks elektroda: Store in a suitable storage solution or distilled water if not used for extended periods.
- Temperaturna sonda: Clean with distilled water after each use.
- Regularly inspect probes for damage or contamination.
6.3. Zamjena baterije
Zamijenite baterije kada se na zaslonu pojavi indikator slabe baterije. Upute za umetanje baterija potražite u odjeljku 4.1.
7. Rješavanje problema
| Problem | Mogući uzrok | Otopina |
|---|---|---|
| Nema zaslona/Uređaj se ne uključuje | Istrošene ili nepravilno postavljene baterije | Provjerite polaritet baterija; zamijenite baterije. |
| Nestabilna očitanja | Dirty or damaged probe; insufficient immersion; air bubbles; incorrect calibration | Clean probe; ensure proper immersion; remove air bubbles; recalibrate. |
| Incorrect pH readings | Expired buffer solutions; dirty/damaged pH electrode; incorrect calibration | Use fresh buffer solutions; clean/replace electrode; recalibrate. |
| Poruka "Greška" na zaslonu | Probe fault; internal device error | Check probe connection and condition. If error persists, contact support. |
8. Specifikacije
| Parametar | Vrijednost |
|---|---|
| Model | GMH 3531 (603925) |
| Measurement Range pH | Typically 0.00 to 14.00 pH |
| Measurement Range Redox | Typically -1999 to +1999 mV |
| Measurement Range Temperature | Typically -5.0 to +100.0 °C |
| Točnost pH | ±0.02 pH (depending on probe) |
| Točnost Temperatura | ±0.2 °C (depending on probe) |
| Napajanje | Battery operated (e.g., 9V block battery or AA batteries) |
| Težina | 170 Grams (without probes) |
Note: Specific ranges and accuracies may vary slightly based on the exact probe used and environmental conditions. Refer to your probe's documentation for detailed specifications.
9. Jamstvo i podrška
9.1. Informacije o jamstvu
GREISINGER products are manufactured to high quality standards. This device comes with a standard manufacturer's warranty against defects in materials and workmanship. The warranty period typically begins from the date of purchase. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, please refer to the official GREISINGER webstranicu ili se obratite lokalnom distributeru.
9.2. Tehnička podrška
Should you encounter any issues not covered in the troubleshooting section, or require further assistance, please contact GREISINGER technical support or your authorized dealer. Provide your model number (GMH 3531) and a detailed description of the problem when seeking support.
GREISINGER Contact Information:
Official GREISINGER Webmjesto