1. Uvod
The Inkbird ITC308S is a reliable and easy-to-use temperature controller designed for precise temperature management in various applications, particularly aquariums. It features dual relay outputs for both heating and cooling devices, ensuring stable temperature control. The unit includes a fully submersible probe for accurate temperature readings in liquid environments.
2. Sigurnosne informacije
- Ensure the power supply matches the controller's requirements (110V for this model).
- Do not immerse the main controller unit in water. Only the probe is submersible.
- Uvijek isključite napajanje prije bilo kakvog održavanja ili instalacije.
- Držite uređaj podalje od djece i kućnih ljubimaca.
- Nemojte koristiti uređaj ako je bilo koji dio oštećen.
3. Sadržaj paketa
- ITC308S Temperature Controller Unit
- Submersible Temperature Probe
- Suction Cup for Probe Mounting
- korisnički priručnik

Slika 3.1: The Inkbird ITC308S Temperature Controller and its included accessories, packaged in a brown box.
4. Proizvod je gotovview
The ITC308S features a main control unit with a dual LED display, showing both the present value (PV) and set value (SV) temperatures. It has dedicated outlets for heating and cooling devices, and a detachable submersible probe for accurate temperature sensing.

Slika 4.1: Nadview of the Inkbird ITC308S controller, showing the display, control buttons, power cord, and probe connection.

Slika 4.2: The dual power outlets, clearly marked for 'HEATING' and 'COOLING' devices.

Slika 4.3: The submersible temperature probe, designed for accurate readings in water, shown with its suction cup.
5. Specifikacije
| Značajka | Detalj |
|---|---|
| Model | ITC-308S |
| Voltage | 120 volti (izmjenična struja) |
| Maksimalno izlazno opterećenje | 1200 W (110 V) |
| Način kontrole temperature | On/Off Control (Heating and Cooling) |
| Tip sonde | Fully Submersible Aquarium Probe |
| Vrsta zaslona | LED Dual Display |
| Materijal | Plastični |
| Boja | Green, Gray and White |
6. Upute za postavljanje
- Spojite sondu: Plug the submersible temperature probe into the designated port on the main controller unit. Use the provided suction cup to secure the probe inside your aquarium or water bath, ensuring it is fully submerged and away from direct heat sources or strong currents.
- Spojite uređaje za grijanje/hlađenje: Plug your heating device (e.g., aquarium heater) into the 'HEATING' outlet and your cooling device (e.g., cooling fan) into the 'COOLING' outlet on the power strip. Ensure devices are rated within the controller's maximum output load (1200W).
- Uključivanje: Plug the main power cord of the ITC308S controller into a standard 110V AC power outlet. The LED display will illuminate, showing the current temperature (PV) and the set temperature (SV).

Slika 6.1: The submersible probe correctly placed within an aquarium, ensuring accurate temperature measurement.
7. Upute za rad
- View Current Temperature (PV): The upper LED display shows the current measured temperature (Process Value).
- View Set Temperature (SV): The lower LED display shows the desired set temperature (Set Value).
- Postavljena temperatura:
- Pritisnite tipku SET button once. The SV display will flash.
- Koristite Gore (▲) or Dolje (▼) tipke za podešavanje željene temperature.
- Pritisnite SET ponovno za potvrdu i spremanje postavke ili pričekajte nekoliko sekundi da se automatski spremi.
- Heating/Cooling Indication: The 'HEATING' or 'COOLING' indicator lights will illuminate when the respective outlet is active.
- Kalibracija temperature: Refer to the detailed instructions in the included paper manual for advanced settings like temperature calibration, differential settings, and alarm parameters. These settings allow fine-tuning of the controller's response.
- Alarm: The controller features over-temperature and sensor fault alarms. If an alarm triggers, the display will show an error code (e.g., 'HHH' for over-temperature, 'LLL' for under-temperature, 'ERR' for sensor fault) and an audible alert may sound. Address the issue promptly.
8. Održavanje
- Čišćenje sonde: Regularly inspect and clean the submersible probe to prevent algae or mineral buildup, which can affect accuracy. Use a soft cloth and mild cleaning solution if necessary.
- Kontrolna jedinica: Wipe the main controller unit with a dry, soft cloth. Do not use abrasive cleaners or immerse it in water.
- Pregled kabela: Periodically check all cables for any signs of wear, cuts, or damage. Replace if necessary.
9. Rješavanje problema
| Problem | Mogući uzrok | Otopina |
|---|---|---|
| Zaslon je prazan | Nema napajanja | Provjerite priključak napajanja i utičnicu. |
| Očitavanje temperature je netočno | Probe dirty or improperly placed; calibration needed | Clean probe, ensure proper submersion, perform temperature calibration. |
| Heating/Cooling device not turning on | Device not plugged in correctly; controller settings incorrect; device malfunction | Verify device connection to correct outlet, check set temperature and differential, test device independently. |
| Alarm sounds frequently | Temperature outside set range; alarm limits too narrow | Adjust set temperature or alarm high/low limits. Ensure heating/cooling devices are functioning. |
| 'ERR' displayed | Kvar senzora | Check probe connection. If error persists, the probe may need replacement. |
10. Jamstvo i podrška
Inkbird products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact details provided in your product packaging or visit the official Inkbird webmjesto. Čuvajte račun za jamstvene zahtjeve.