This manual provides detailed instructions for the safe and efficient operation of your DeWin DC 24V Digital Display Timer Delay Cycle Relay Module. Please read this manual thoroughly before installation and use, and keep it for future reference.

The module is designed for precise timing control in various applications, featuring a digital display for easy parameter setting and monitoring. It offers low power consumption and is built with high-quality, durable materials.

2. Sigurnosne informacije

Upozorenje: Electrical components can be dangerous. Always ensure power is disconnected before installation or maintenance. Professional installation is highly recommended to prevent electrical shock or damage to the device.

  • Do not operate the module beyond its specified voltage (DC 24 V).
  • Ensure all wiring connections are secure and correct according to the wiring diagram.
  • Keep the module away from moisture, extreme temperatures, and corrosive environments.
  • Do not attempt to modify or disassemble the module, as this may void the warranty and pose safety risks.

3. Proizvod je gotovview

The DeWin DC 24V Digital Display Timer Delay Cycle Relay Module is a compact and portable control board designed for various timing applications. It features a clear digital display and intuitive buttons for setting operational parameters.

3.1 Ključne značajke

  • Digital display for precise time and parameter visualization.
  • Three adjustable parameter sets: P0 (timing range), P1 (working mode), P2 (display brightness).
  • Izdržljiva konstrukcija s visokokvalitetnim materijalima.
  • Mala potrošnja energije.
  • Compact size: 7.1 x 3.9 x 2.5 cm.

3.2 Identifikacija komponente

DeWin Timer Relay Module with labeled buttons and display
Slika 1: Prednja strana view of the module with labeled components.

This image shows the front panel of the DeWin timer relay module. Key components are labeled: "UP" button (top left), "DOWN" button (bottom left), "SET" button (top right), "OK" button (bottom right), "Time1" display (top center), "Time2" display (bottom center), and an "OUT" LED indicator light.

  • Digital Displays (Time1, Time2): Show current time values or parameter settings.
  • Gumb GORE: Koristi se za povećanje vrijednosti ili navigaciju kroz izbornike.
  • Tipka DOLJE: Koristi se za smanjenje vrijednosti ili navigaciju kroz izbornike.
  • Gumb SET: Enters parameter setting mode.
  • Gumb OK: Confirms settings and restarts the timer.
  • IZLAZNA LED: Indicates relay output status.

4. Specifikacije

ParametarVrijednost
Operativni svtageDC 24 volti
MarkaDeWin
MaterijalAkrilonitril butadien stiren
Dimenzije predmeta (D x Š x V)7.1 x 3.9 x 2.5 centimetara
ModelDEWINvbhaozkn3s
Zemlja podrijetlaKina

5. Postavljanje i ožičenje

Before connecting the module, ensure the power supply is disconnected. Refer to the wiring diagram below for correct connections.

Wiring diagram for DeWin Timer Relay Module
Slika 2: Dijagram ožičenja.

This diagram illustrates how to connect the DeWin timer relay module. It shows connections for a DC/AC power source (Red + and Black -) and a load (e.g., a fan) connected to the module's output terminals. Ensure positive and negative terminals are correctly matched.

  • Connect the DC 24V power supply to the designated input terminals (usually marked + and -).
  • Connect your load (e.g., motor, light) to the output terminals of the relay. Ensure the load's power requirements are within the relay's specifications.
  • Double-check all connections for polarity and security before applying power.

6. Upute za rad

The module features three main parameter sets (P0, P1, P2) for configuration. Use the SET, UP, DOWN, and OK buttons to navigate and adjust settings.

Image showing P0, P1, P2 parameter descriptions
Figure 3: Parameter Descriptions.

This image displays the three main parameter settings for the DeWin Delay Relay Module: P0 for timing range, P1 for working mode, and P2 for display brightness adjustment.

6.1 Setting Parameters (P0, P1, P2)

  1. Uđite u način podešavanja: Pritisnite i držite SET button until the display changes to show parameter options (e.g., P0).
  2. Select Parameter: Koristite UP or DOLJE buttons to cycle through P0, P1, P2.
  3. Adjust Parameter Value: Once the desired parameter (e.g., P0) is displayed, press the SET button again to enter its value adjustment mode. Use UP or DOLJE za promjenu vrijednosti.
  4. Potvrdi i spremi: After setting the value, press the OK button to save the setting and return to the parameter selection menu. Repeat for P1 and P2 as needed.
  5. Izlaz iz načina podešavanja: Pritisnite i držite SET button again to exit the setting mode and return to normal operation.

6.2 OK Button Functions

The OK button serves two primary functions:

  • Save and Start: After setting parameters, pressing the OK button saves the configuration and initiates the timer's operation.
  • Restart Timer: If the timer has completed its cycle and you wish to restart it, a short press of the OK button will re-trigger the function and restart the timer.
DeWin Timer Relay Module with text explaining restart function
Figure 4: Restarting the Timer.

This image shows two DeWin timer relay modules. The text overlay explains: "Trigger the function again. After the timer has finished working normally, it needs to work again. Short press the confirm button to restart the timer."

7. Održavanje

  • Čišćenje: Use a soft, dry cloth to clean the module. Do not use abrasive cleaners or solvents.
  • Inspekcija: Periodically check wiring connections for looseness or signs of wear.
  • Skladištenje: If storing the module for an extended period, keep it in a dry, dust-free environment.

8. Rješavanje problema

ProblemMogući uzrokOtopina
Modul se ne uključuje.Incorrect power connection, no power supply, faulty module.Provjerite vol. Napajanjatage (DC 24V). Verify power wiring polarity and connections. If issues persist, the module may be faulty.
Relay does not activate.Incorrect parameter settings, faulty wiring to load, load exceeding relay capacity.Review P0 and P1 settings. Check wiring to the load. Ensure the load's current/voltage is within the relay's limits.
Zaslon je taman ili nečitljiv.P2 (display brightness) setting is too low.Adjust P2 parameter to increase display brightness.

Ako naiđete na probleme koji nisu ovdje navedeni ili ako rješenja ne riješe problem, obratite se korisničkoj podršci.

9. Jamstvo i podrška

This product comes with a standard manufacturer's warranty. Please refer to your purchase documentation for specific warranty terms and duration. For technical support, troubleshooting assistance, or warranty claims, please contact your retailer or the manufacturer directly.

Manufacturer: DEWIN

Model: DEWINvbhaozkn3s

© 2023 DeWin. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.