1. Uvod
This manual provides essential information for the safe installation, operation, and maintenance of the Siemens B2125 125-Amp Double Pole Circuit Breaker. Please read this manual thoroughly before attempting any installation or operation. Retain this manual for future reference.
2. Sigurnosne informacije
WARNING: Risk of Electric Shock or Fire.
- Installation and servicing of this circuit breaker must be performed by qualified electrical personnel only.
- Always disconnect power at the main service panel before working on electrical equipment. Verify that power is off using a voltage tester.
- Follow all local and national electrical codes and regulations.
- Do not use this circuit breaker if it appears damaged.
- Ensure proper wire sizing and torque specifications are met for all connections.
3. Značajke proizvoda
The Siemens B2125 is a reliable thermal-magnetic circuit breaker designed for panel board mounting. Key features include:
- Type BL: Specifically designed for Siemens panel boards.
- Double Pole: Provides protection for two electrical phases or a single 240-volt circuit.
- 125-Amp Ocjena: Suitable for circuits requiring up to 125 amperes of protection.
- 10KAIC Interrupting Rating: Capable of safely interrupting fault currents up to 10,000 Amperes.
- Bolt-On Mount: Ensures secure and stable connection within the panel board.
- UL naveden: Certified for safety and performance standards.
4. Postavljanje i instalacija
Installation of the Siemens B2125 circuit breaker requires adherence to safety protocols and electrical codes. This is a general guide; consult a qualified electrician for specific installation requirements.
- Prekid napajanja: Turn off the main power supply to the electrical panel at the utility meter or main disconnect. Verify zero voltage s odgovarajućim uređajem za ispitivanje.
- Pristup panelu: Pažljivo uklonite poklopac električne ploče kako biste otkrili sabirnice i područje ožičenja.
- Položaj prekidača: Identify an available space on the panel board's bus bar compatible with a bolt-on type BL breaker.
- Montaža: Align the circuit breaker's bolt-on connectors with the bus bar terminals. Securely fasten the breaker to the bus bar using the provided bolts, ensuring a tight electrical connection.
- Ožičenje: Connect the load wires to the appropriate terminals on the circuit breaker. For a double pole breaker, connect one phase wire to each terminal. Ensure the wires are stripped to the correct length and inserted fully into the terminals. Tighten the terminal screws to the torque specifications indicated on the breaker or in the panel documentation.
- Poklopac ploče: Once all connections are secure and verified, replace the electrical panel cover.
- Obnova napajanja: Vratite napajanje na glavnu servisnu ploču.

Figure 1: Siemens B2125 125-Amp Double Pole Circuit Breaker, front-side view, showing the 125 amp rating and product labels.

Slika 2: Prednja strana view of the Siemens B2125 circuit breaker, highlighting the 125 amp trip indicators and terminal screws.
5. Upute za rad
The Siemens B2125 circuit breaker operates automatically to protect electrical circuits from overcurrents and short circuits. It has two primary states: ON and TRIPPED/OFF.
- UKLJUČENO pozicija: When the handle is in the 'ON' position, power is supplied through the breaker to the connected circuit.
- ISKLJUCENI položaj: In the event of an overcurrent or short circuit, the breaker will automatically move to a 'TRIPPED' position (often midway between ON and OFF) to interrupt the power flow and protect the circuit.
- Resetiranje isključenog prekidača: To restore power after a trip, first move the handle fully to the 'OFF' position, then push it firmly to the 'ON' position. If the breaker immediately trips again, there is likely a persistent fault in the circuit that needs to be investigated by a qualified electrician.
6. Održavanje
Circuit breakers generally require minimal maintenance. However, periodic visual inspection is recommended.
- Vizualni pregled: Annually, or as local codes require, have a qualified electrician inspect the circuit breaker and its connections for any signs of overheating, loose wires, or physical damage.
- Čišćenje: Ensure the area around the breaker is free from dust and debris. Do not use liquids for cleaning inside the electrical panel.
- Testiranje: Do not routinely test the trip mechanism by intentionally creating a fault. This can stress the breaker and connected equipment.

Slika 3: Bočna strana view of the Siemens B2125 circuit breaker, showing its compact design and mounting points.
7. Rješavanje problema
If your Siemens B2125 circuit breaker is not functioning as expected, consider the following:
- Često isključivanje prekidača: This indicates an overload or a short circuit in the connected wiring or appliances. Disconnect appliances from the circuit and try resetting the breaker. If it still trips, consult a qualified electrician to identify and resolve the underlying electrical fault.
- Prekidač se ne resetira: If the breaker handle does not stay in the 'ON' position after being moved to 'OFF' and then 'ON', there is likely a persistent fault. Do not force the handle. Contact a qualified electrician.
- Nema napajanja strujnog kruga (prekidač uključen): Ensure the main power supply to the panel is active. Check for loose connections at the breaker terminals (only by a qualified electrician with power off). If the issue persists, professional diagnosis is required.
8. Specifikacije
| Specifikacija | Vrijednost |
|---|---|
| Marka | SIEMENS |
| Broj modela | B2125 |
| Trenutna ocjena | 125 Amps |
| Broj Poljaka | 2 |
| Voltage Ocjena | 120/240 volti |
| Prekidanje ocjene | 10KAIC |
| Tip prekidača | Termo-magnetski, standardni |
| Vrsta montaže | Montaža na vijke |
| Dimenzije proizvoda | 4 x 3 x 2 inča |
| Težina artikla | 8 unci |
| UPC | 0783643263666 |

Slika 4: Stražnji dio view of the Siemens B2125 circuit breaker, displaying the bolt-in connectors and additional product labeling.
9. Informacije o jamstvu
Siemens strongly recommends against the use of "used" breakers. The installation of used breakers in a Siemens panel will void the warranty on the panel. Siemens does not sell used breakers and has not approved any third-party sellers to do so. For specific warranty details, please refer to the official Siemens warranty documentation or contact Siemens customer support.
10. Podrška i kontakt
For technical assistance, product inquiries, or to locate authorized service centers, please visit the official Siemens website or contact their customer support directly. Always provide the model number (B2125) when seeking support.
You can find more information about Siemens products at the Siemensova trgovina na Amazonu.





