Johnson Controls MR4PMUHV-12C

Johnson Controls MR4PMUHV-12C Korisnički priručnik za upravljanje odmrzavanjem

1. Uvod

The Johnson Controls MR4PMUHV-12C Defrost Control is engineered for use in refrigeration and freezer units, supporting both hot gas and electric heat defrost methods. This control unit offers flexible defrost termination options, allowing selection between time-based or temperature-based methods. It integrates essential control functions including compressor management, defrost cycle management, fan operation control, and alarm management, providing a comprehensive solution for HVAC systems.

Johnson Controls MR4PMUHV-12C Defrost Control unit with two coiled temperature sensors

Slika 1: Johnson Controls MR4PMUHV-12C Defrost Control unit and included temperature sensors. The central gray unit features a digital display and control buttons, while two coiled gray cables with metallic tips represent the temperature sensors.

2. Što je u kutiji

3. Ključne značajke

4. Postavljanje i instalacija

Proper installation is crucial for the safe and efficient operation of the defrost control. Always ensure power is disconnected before beginning any installation or wiring procedures.

  1. Sigurnost prije svega: Disconnect all power to the refrigeration or freezer unit before proceeding. Follow all local electrical codes and safety guidelines.
  2. Montaža: Select a suitable location for mounting the control unit and, if applicable, the separate relay pack. Ensure adequate ventilation and protection from moisture. The flexible design allows for combined or separate mounting.
  3. Ožičenje:
    • Connect the 24VAC power supply to the designated terminals on the control unit.
    • Wire the compressor, fans, and defrost heaters to the heavy-duty relay terminals as per the wiring diagram provided with the product.
    • Connect any external alarm systems to the dedicated alarm terminals.
  4. Ugradnja senzora: Install the temperature sensors in the appropriate locations within the evaporator or process area as required for accurate temperature monitoring. Ensure sensor cables are routed safely and securely.
  5. Početno napajanje: Once all connections are secure and verified, restore power to the unit. The control unit display should illuminate.

5. Operacija

After successful installation, the MR4PMUHV-12C is ready for configuration and operation.

  1. Prikaz prekoview: Upon power-up, the digital display will show the current temperature. Pressing the designated button (refer to product-specific labeling) allows toggling between evaporator and process temperature readings.
  2. Setting Defrost Parameters: Access the control unit's menu (typically via dedicated buttons) to configure defrost settings. This includes:
    • Interval odmrzavanja: Set the frequency at which defrost cycles occur.
    • Defrost Duration: Specify the maximum time for a defrost cycle.
    • Defrost Termination Method: Choose between time-based termination (defrost ends after a set duration) or temperature-based termination (defrost ends when a specific temperature is reached).
    • Fan Delay: Configure any fan delay settings post-defrost.
  3. Postavke alarma: Configure temperature thresholds for alarms to ensure optimal operating conditions and prompt notification of deviations.
  4. Praćenje: Regularly check the display for current temperatures and system status.

6. Održavanje

Routine maintenance helps ensure the longevity and reliable performance of your defrost control unit.

7. Rješavanje problema

Ovaj odjeljak pruža smjernice za uobičajene probleme. Za složene probleme obratite se kvalificiranom servisnom osoblju.

8. Specifikacije

Broj modelaMR4PMUHV-12C
Dimenzije proizvoda10.5 x 5.5 x 6.5 inča
Težina artikla3.17 Pounds (3.2 Pounds listed elsewhere)
MarkaJohnson Controls
MaterijalPlastični
Radna temperatura32 stupnja Fahrenheita (0°C)
ProizvođačJohnson Controls Inc.

9. Jamstvo i podrška

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly or refer to the official documentation included with your purchase. Keep your proof of purchase for warranty claims.

Johnson Controls Contact Information: Please visit the official Johnson Controls webstranicu za najnovije kontaktne podatke i resurse za podršku.

Povezani dokumenti - MR4PMUHV-12C

prijeview Johnson Controls A421 Series Electronic Temperature Controls with Off-Cycle Defrost Installation Instructions
Comprehensive installation guide for Johnson Controls PENN A421 Series Electronic Temperature Controls, featuring off-cycle defrost functionality. Covers product overview, applications, dimensions, mounting, wiring, setup, adjustments, troubleshooting, and technical specifications.
prijeview A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures
This technical bulletin from Johnson Controls details the A419 Series Electronic Temperature Controls, designed for single-stage refrigeration and HVAC applications. It covers features, benefits, NEMA 1 and NEMA 4X enclosure options, operation, wiring, adjustments, troubleshooting, fault codes, ordering information, and technical specifications.
prijeview Johnson Controls A19 Series Remote Bulb Control - Temperature Sensors
Detailed specifications and selection guide for Johnson Controls A19 Series remote bulb temperature controls, used in HVAC, heating, ventilating, and refrigeration applications. Includes model numbers, electrical ratings, and features.
prijeview Daljinski upravljači žarulja serije PENN A19 | Johnson Controls
Kataloška stranica za daljinske upravljače žarulja PENN serije A19, s pojedinačnim...tagRegulatori temperature s tekućinom ispunjenim senzorskim elementima. Uključuje tablice odabira, tehničke specifikacije, rezervne dijelove i kontaktne podatke.
prijeview Hx 3 Priručnik za korisnike termostata s dodirnim zaslonom
Ovaj korisnički priručnik pruža detaljne upute i smjernice za termostat s dodirnim zaslonom Johnson Controls Hx 3 (model: S1-THXU430W), koje obuhvaćaju instalaciju, značajke, rad, povezivanje aplikacija i postavke.
prijeview Upute za ugradnju zamjenskih upravljačkih elemenata povremenog pilot paljenja serije G600
Sveobuhvatan vodič za instalaciju, montažu, ožičenje, postavljanje, rad i rješavanje problema za zamjenske kontrole paljenja s prekidima serije Johnson Controls G600.