1. Uvod

This manual provides essential information for the safe and effective use of the Renishaw OMP40-2 Machine Tool Probe Kit. The OMP40-2 is an ultra-compact 3D touch-trigger probe designed for precise workpiece set-up and inspection on small to medium machining centers, including those with high-speed capabilities and small HSK and spindle tapers.

Please read this manual thoroughly before installation, operation, or maintenance to ensure optimal performance and safety.

2. Ključne značajke

Ispred view of the Renishaw OMP40-2 probe

Slika 2.1: Prednja strana view of the Renishaw OMP40-2 probe, showing its compact design.

3. Sadržaj paketa

Upon opening the Renishaw OMP40-2 Machine Tool Probe Kit, verify that all components are present and undamaged. The standard kit typically includes:

Renishaw OMP40-2 Machine Tool Probe Kit in its open box

Figure 3.1: The Renishaw OMP40-2 probe kit as packaged in its box, showing the probe, manual, and batteries.

Contents of the Renishaw OMP40-2 kit laid out: probe, manual, and batteries

Figure 3.2: Individual components of the OMP40-2 kit, including the probe, quick start guide, and batteries.

4. Postavljanje i instalacija

Proper installation is crucial for the accuracy and longevity of your OMP40-2 probe. Refer to the detailed installation guide provided with your kit for specific machine interface instructions.

4.1 Ugradnja baterije

  1. Unscrew the battery cap on the probe unit.
  2. Insert the two 1/2 AA Lithium batteries, ensuring correct polarity as indicated inside the compartment.
  3. Securely fasten the battery cap.
Close-up of the Renishaw OMP40-2 probe and batteries inside the packaging

Figure 4.1: The OMP40-2 probe and its batteries, ready for installation.

4.2 Probe Mounting

4.3 System Pairing and Calibration

The OMP40-2 probe communicates optically with a receiver unit on the machine. Follow these general steps:

  1. Power on the machine tool and the probe system receiver.
  2. Initiate the pairing sequence as per the machine tool controller's instructions and the OMP40-2 quick start guide.
  3. Perform a calibration routine using a known reference artifact (e.g., a calibration sphere) to establish probe offsets and ensure measurement accuracy.
  4. Verify successful communication and calibration before proceeding with measurements.

5. Upute za rad

The Renishaw OMP40-2 probe is designed for automated measurement cycles. Operation is typically controlled via the machine tool's CNC program.

5.1 Workpiece Set-up

5.2 In-Process Measurement

5.3 Post-Process Inspection

Bilješka: Always ensure the probe stylus is clean and undamaged before any measurement cycle. Refer to your machine tool's programming manual for specific G-code or macro instructions for probing cycles.

6. Održavanje

Regular maintenance ensures the accuracy and reliability of your Renishaw OMP40-2 probe.

6.1 Čišćenje

6.2 Zamjena baterije

6.3 Stylus Inspection and Replacement

7. Rješavanje problema

This section addresses common issues you might encounter with your OMP40-2 probe.

ProblemMogući uzrokOtopina
No signal/communication lossLow batteries, obstructed optical path, probe out of range, receiver fault.Check/replace batteries. Clean optical window on probe and receiver. Ensure probe is within receiver's line of sight and operating range. Consult machine tool manual for receiver diagnostics.
Netočna mjerenjaUncalibrated probe, damaged stylus, debris on stylus, thermal drift, machine geometry errors.Perform probe calibration. Inspect and replace damaged stylus. Clean stylus tip. Allow machine to reach thermal stability. Verify machine tool accuracy.
Probe not triggeringStylus stuck, probe damaged, incorrect trigger force setting (if adjustable).Inspect stylus for obstruction or damage. If probe is damaged, contact Renishaw support. Check machine parameters for trigger force settings.

For issues not listed here, or if solutions do not resolve the problem, contact Renishaw technical support or your authorized distributor.

8. Tehničke specifikacije

The following specifications are typical for the Renishaw OMP40-2 probe. Refer to the official Renishaw datasheet for complete and up-to-date specifications.

9. Jamstvo i podrška

9.1 Informacije o jamstvu

The Renishaw OMP40-2 Machine Tool Probe Kit is typically sold with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your product or contact Renishaw directly. Keep your proof of purchase for warranty claims.

9.2 Tehnička podrška

For technical assistance, service, or spare parts, please contact Renishaw customer support or your local authorized Renishaw distributor. Contact information can usually be found on the Renishaw official webmjestu ili pakiranju proizvoda.

Proizvođač: Renishaw

Webstranica: www.renishaw.com

Povezani dokumenti - OMP40-2

prijeview Renishaw OMP40-2 Optical Machine Probe Installation Guide
This guide provides comprehensive installation, setup, and configuration details for the Renishaw OMP40-2 optical machine probe, a key component for automated workpiece inspection and job setup in CNC machining environments.
prijeview Renishaw OMP40-2 Optical Machine Probe: Specifications and Performance
Detailed specifications, dimensions, installation guide, and performance envelopes for the Renishaw OMP40-2 optical machine probe, designed for workpiece inspection and job set-up on small to medium machining centres.
prijeview Vodič za instalaciju Renishaw OSI/OSI-D s OMM-2C: Postavljanje i rad sustava
Sveobuhvatni vodič za instalaciju sustava Renishaw OSI/OSI-D s višestrukim optičkim sučeljem za sonde OMM-2C. Obuhvaća postavljanje, konfiguraciju, održavanje i rješavanje problema za industrijske CNC primjene.
prijeview Renishaw RMP60 Quick-Start Guide
Quick-start guide for the Renishaw RMP60 radio probe, detailing initial setup and operation for machine tool inspection.
prijeview Renishaw Probe Software for Machine Tools: Programs and Features
Explore Renishaw's comprehensive probe software for machine tools, detailing programs and features for machining centres, lathes, and multi-axis applications. Discover Inspection Plus, Productivity+™ Scanning Suite, AxiSet™ Check-Up, and smartphone apps for enhanced manufacturing efficiency.
prijeview Renishaw RMP60 (QE) Radio Machine Probe Installation Guide
Comprehensive installation guide for the Renishaw RMP60 (QE) radio machine probe. Covers setup, configuration, system integration with RMI-Q/RMI-QE, maintenance, and troubleshooting for industrial metrology applications.