1. Uvod
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Turck MS96-12R/24VDC Signal Processor. This device is designed for precise signal processing, offering two relay outputs specifically for monitoring flow and temperature in industrial applications. It is engineered to connect seamlessly with various flow sensors, providing reliable data and control capabilities.

Slika 1: Prednja strana view of the Turck MS96-12R/24VDC Signal Processor. The unit features a black housing with a yellow top section, indicating various connection points and status indicators.
2. Postavljanje
Proper setup is crucial for optimal performance and safety. Ensure all power is disconnected before proceeding with installation.
2.1 Montaža
The MS96-12R/24VDC is designed for DIN rail mounting. Securely attach the unit to a standard DIN rail in a suitable enclosure, ensuring adequate ventilation.
2.2 Spajanje ožičenja
Refer to the wiring diagram on the device label for specific terminal assignments. Ensure all connections are secure and comply with local electrical codes.
- Napajanje: Connect 24VDC to the designated power terminals. Observe polarity.
- Ulazi senzora: Connect flow and temperature sensors to the appropriate input terminals.
- Relejni izlazi: Connect the two relay outputs to the control circuits or indicators as required for flow and temperature monitoring.
Oprez: Incorrect wiring can damage the device or connected equipment.
3. Upute za rad
Once installed and powered, the MS96-12R/24VDC will begin processing signals from connected sensors.
3.1 Početno uključivanje
Upon applying 24VDC power, the power indicator LED should illuminate. The device will perform a self-test. Ensure all connected sensors are operational.
3.2 Signal Monitoring
The processor continuously monitors the input signals from the flow and temperature sensors. Internal logic processes these signals to determine the status of the monitored parameters.
3.3 Relay Output Functionality
The two relay outputs are independently configurable (if applicable, refer to advanced programming guide) to trigger based on predefined thresholds for flow and temperature. When a monitored parameter exceeds or falls below a set point, the corresponding relay will activate, providing a control signal to external systems.
- Relej 1: Typically assigned for Flow monitoring.
- Relej 2: Typically assigned for Temperature monitoring.
Bilješka: Specific threshold settings and calibration procedures may require additional software or hardware, not covered in this basic manual. Consult the full technical documentation for advanced configuration.
4. Održavanje
The MS96-12R/24VDC is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.
- Čišćenje: Keep the unit free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
- Integritet veze: Povremeno pregledavajte sve spojeve ožičenja kako biste bili sigurni da su sigurni i bez korozije.
- Uvjeti okoliša: Osigurajte da radno okruženje ostane unutar navedenih raspona temperature i vlažnosti kako biste spriječili oštećenja.
Upozorenje: Isključite napajanje prije bilo kakvog održavanja ili čišćenja.
5. Rješavanje problema
This section addresses common issues you might encounter with the MS96-12R/24VDC Signal Processor.
| Problem | Mogući uzrok | Otopina |
|---|---|---|
| Nema indikatora napajanja | Nema napajanja; Neispravno ožičenje; Pregorjeli osigurač (vanjski) | Check 24VDC power supply; Verify wiring connections; Check external fuse. |
| Relejni izlazi se ne aktiviraju | Sensor not connected or faulty; Thresholds not met; Incorrect configuration | Verify sensor operation and connection; Check monitored parameters against thresholds; Consult advanced documentation for configuration. |
| Netočna očitanja | Faulty sensor; Sensor not calibrated; Electrical interference | Test or replace sensor; Calibrate sensor if possible; Ensure proper grounding and shielding. |
Ako problem i dalje postoji nakon isprobavanja ovih rješenja, obratite se tehničkoj podršci.
6. Specifikacije
Key technical specifications for the MS96-12R/24VDC Signal Processor:
- Model: MS96-12R/24VDC
- Marka: Turck
- Funkcija: Signal processor for Flow and Temperature Monitoring
- Izlazi: 2 relejna izlaza
- Napajanje: 24VDC
- Težina artikla: 6.99 funti
- ASIN: B092RF5MDD
- UPC: 790409678299
- Proizvođač: TURČIN
- Prvo dostupno: 16. travnja 2021
7. Jamstvo i podrška
For information regarding product warranty, please refer to the official Turck warranty policy available on their website or contact your local distributor. Technical support is available for assistance with installation, operation, and troubleshooting.
Za dodatnu pomoć posjetite Turck official webmjesto ili kontaktirajte njihov odjel za korisničku podršku.