Weidmuller UR20-FBC-MOD-TCP-ECO

Weidmuller UR20-FBC-MOD-TCP-ECO I/O Module

Priručnik s uputama

1. Uvod

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Weidmuller UR20-FBC-MOD-TCP-ECO I/O Module. Please read this manual thoroughly before attempting to install or operate the device.

The UR20-FBC-MOD-TCP-ECO is an industrial I/O module designed for robust performance in various automation applications. It features a 24 VDC input voltage and push-in termination style for reliable connections.

2. Sigurnosne informacije

  • Always disconnect power before installing, wiring, or servicing the module.
  • Instalaciju i održavanje treba obavljati samo kvalificirano osoblje.
  • Osigurajte pravilno uzemljenje kako biste spriječili strujni udar i osigurali ispravan rad.
  • Operate the module within the specified environmental conditions (temperature, humidity).
  • Do not expose the module to excessive moisture or corrosive substances.

3. Proizvod je gotovview

The Weidmuller UR20-FBC-MOD-TCP-ECO is a compact I/O module designed for distributed control systems. It integrates seamlessly into industrial networks, providing reliable data acquisition and control capabilities.

Weidmuller UR20-FBC-MOD-TCP-ECO I/O Module
Figure 1: Weidmuller UR20-FBC-MOD-TCP-ECO I/O Module. An angled view of the Weidmuller UR20-FBC-MOD-TCP-ECO I/O module, showing its compact black housing, various connection ports, and labeling. Two Ethernet ports are visible on the front face.

3.1 Ključne značajke

  • Kompaktan dizajn za ugradnju koja štedi prostor.
  • Push-in termination technology for quick and reliable wiring.
  • Širok raspon radnih temperatura (-20°C do +60°C).
  • Ethernet/TCP communication capabilities.

4. Postavljanje i instalacija

4.1 Montaža

  1. Ensure the DIN rail is securely mounted in a suitable enclosure.
  2. Align the module's DIN rail clip with the top edge of the DIN rail.
  3. Čvrsto pritisnite modul prema dolje dok ne klikne na DIN šinu.
  4. Verify that the module is securely fastened and does not wobble.

4.2 Ožičenje

The UR20-FBC-MOD-TCP-ECO utilizes push-in termination for electrical connections. Ensure all wires are stripped to the recommended length before insertion.

  1. Napajanje: Connect a stable 24 VDC power supply to the designated power terminals. Observe correct polarity (+ and -).
  2. Mrežna veza: Connect standard Ethernet cables to the RJ45 ports for network communication.
  3. I/O veze: Connect field devices to the appropriate input/output terminals as per your system design. Refer to the system documentation for specific pin assignments.
  4. Ensure all connections are firm and free from loose strands.

4.3 Početno uključivanje

After all connections are made and verified, apply power to the module. Observe the status indicator LEDs for proper initialization.

5. Operacija

Once powered, the UR20-FBC-MOD-TCP-ECO module will establish communication with the connected network controller. The module's operational status can be monitored via its integrated LED indicators.

5.1 Indikatori statusa

Refer to the module's labeling for the exact meaning of each LED. Typically, these include:

  • LED za napajanje: Označava stanje napajanja.
  • LED statusa mreže: Indicates network connection and communication activity.
  • I/O Status LEDs: Indicate the status of individual input/output channels.

5.2 Mrežna komunikacija

The module communicates over Ethernet using TCP/IP protocols. Configuration of network parameters (e.g., IP address) is typically performed via the connected controller or a dedicated configuration tool.

6. Održavanje

Regular maintenance ensures the longevity and reliable operation of the I/O module.

  • Čišćenje: Periodically clean the module's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is disconnected before cleaning.
  • Inspekcija: Regularly inspect wiring connections for tightness and signs of damage or corrosion. Check for any physical damage to the module housing.
  • Ažuriranja firmvera: Consult the Weidmuller website or your system integrator for information on available firmware updates. Follow all instructions carefully when performing updates.

7. Rješavanje problema

Ovaj odjeljak pruža smjernice za uobičajene probleme. Za složene probleme obratite se tehničkoj podršci.

ProblemMogući uzrokOtopina
Nema LED indikacije napajanjaNo power supply; incorrect wiring; faulty module.Check 24 VDC power supply; verify wiring polarity; test with a known good power source.
Network Status LED off/flashing incorrectlyNo network connection; incorrect network settings; faulty cable.Check Ethernet cable connection; verify network configuration (IP address, subnet mask); replace cable.
I/O not respondingIncorrect I/O wiring; faulty field device; software configuration error.Verify I/O wiring; test field device independently; check controller software configuration.

8. Tehničke specifikacije

ParametarVrijednost
Broj modelaUR20-FBC-MOD-TCP-ECO
Broj dijela2659700000
ProizvođačWeidmuller
Ulazni voltage24 VDC
Stil prekidaUgurati
Minimalna radna temperatura-20°C
Maksimalna radna temperatura+60°C
Težina artikla6.99 funti

9. Informacije o jamstvu

Weidmuller products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the official Weidmuller warranty statement available on their webstranicu ili se obratite lokalnom distributeru. Sačuvajte dokaz o kupnji za slučaj zahtjeva za jamstvo.

10. Tehnička podrška

For technical assistance, product inquiries, or service requests, please contact your authorized Weidmuller distributor or visit the official Weidmuller webstranica za resurse podrške i kontakt informacije.