Tehnički podaci
- Napajanje: 200 – 240VAC 50-60Hz
- Ocjena kontakta: 230 Vac 10(3)A
- Temperatura okoline: 0…45˚C
- Automatsko djelovanje: Type 1. C.
- Klase uređaja: Uređaj klase II

- Stupanj onečišćenja: Stupanj onečišćenja 2
- IP ocjena: IP20
- Nazivni impuls Voltage: Otpornost na voltage udar 2500V prema EN 60730
Kako vaš TR1 TR2V2 radi
- Your TR1 TR2V2 is used to send a wireless signal from one location to another when running Cables is difficult, expensive, or otherwise not an option.
- The product comprises two devices: a TR1V2 and a TR2V2. Both devices are pre-paired during manufacturing for user convenience.
- When 230V is applied to the Live in terminal of the TR1V2, the COM and Live out connection closes, which sends voltage from Live out on the TR2V2.
- It is possible to send a wireless signal in one direction or both.
- When a signal is sent from the TR1V2 to the TR2V2, a green light will activate on the TR2V2.
- When the TR2V2 sends a signal to the TR1V2, a green light will activate on the TR1V2.
- Common uses include sending a signal from a programmer to a boiler or hot water cylinder that is in a different location. These are also used to control pump overrun and many other applications.
- It is possible to have more than one set of TR1, TR2V, 2and, where required.
- Please see pages 9-13 for wiring examples
Unutarnji dijagram ožičenja za TR1TR2V2
OPREZ: Installation should only be carried out by a qualified person and by wiring regulations.
Switching Options
Mrežno prebacivanje
- Link L to 3
Niski volumentage Prebacivanje
- Remove the external controls link from the boiler PCB.
- Connect 2 and 3 to these terminals.
Montaža i ugradnja
- The TRIV2 should be wall-mounted in an area within 30 metres of the TR2V2. Both TRIV2 & TR2V2 must be mounted more than 25cm away from metal objects, as this will affect communication. The TRIV2 & TR2V2 should be installed at least 1 metre from any electronic devices such as radio, TV, microwave, ve, or wireless network adapter. They can be fitted to
- Single-gang recessed back box.
- Kutije za nadgradnu ugradnju
- Directly mounted on a wall.
- Use a Phillips screwdriver to loosen the screws of the backplate on the bottom of the TRIV2 & TR2V2, lift upwards from the bottom, and remove the backplate.
- Screw the backplate to the wall with the screws provided.
- Spojite stražnju ploču prema dijagramu ožičenja.
- Mount the TRIV2 & TR2V2 on the backplate, making sure the pins and the backplatcontactsts are making a sound connection. Push the TRIV2 & TR2V2 flush to the surface and tighten the screws of the backplate from the bottom.m



Tipka / LED Opis

Priručnik Press to activate or deactivate the Live out terminal.
Poveži se Hold for 3 seconds to initialise the pairing process. The RF light will flash.
Resetiraj Press to reset the T, R1, TR2V2.
Bilješka: The connection procedure is not required as both TR1 & TR2V2 are pre-paired
LED opis
| LED | Boja | Opis |
| Uživo u LED-u | crvena | Nema voltage on the Live terminal. |
| zelena | Postoji svtage na Live in terminalu – Sada će se RF signal poslati na drugi RF glavni prekidač kako bi se aktivirao Live out terminal. | |
| RF LED | Bijela | Stalno bijelo LED svjetlo koje pokazuje da je termostat spojen. |
| RF svjetlo će dvostruko zatreperiti kada je termostat isključen. Provjerite uparivanje termostata. | ||
| Bilješka: RF svjetlo će povremeno treptati kada sustav šalje i prima signal za komunikaciju. | ||
| Bilješka: The RF light will blink once every second when in RF pairing by holding Connect. Press the Manual to exit from this state. | ||
| LED dioda s aktivnim svjetlom | crvena | Nije primljen RF aktivacijski signal s drugog RF glavnog prekidača. |
| zelena | RF activation signal has been received from the other RF Mains Switch. |
To connect the TRI TR2V2
Napomena: When installing TRI TR2V2 RF mains switches, both TRI &TR2V2 are pre-paired. The procedures below are not required.
On TR1V2:
- Stani
for 3 seconds until the RF LED flashes white.
On TR2V2:
- Stani
3 sekunde. - The RF LED will begin to flash, and the Live out LED will appear solid green.
- When connected, all three LEDs will appear solid.
On TR1V2:
- Pritisnite tipku
to exit the pairing mode. - After connecting successfully, the RF LED on both TR1V2 & TR2V2will appear solid.
To disconnect the TRI TR2V2
- Stani
for 3 seconds until the RF LED flashes white. - Stani
for 10 seconds until the Live in LED appears solid red.
On TR2V2:
- Stani
for 3 seconds until the RF LED flashes white. - Stani
Connect for 10 seconds until the Live in & Live out LED appears solid red.
On TRIV2:
- Pritisnite
izaći. - The TRI TR2V2 is now disconnected.
Ožičenje Examples
Example One way RF Switch: Programmer to Boiler – Mains Switching
TR1V2
On TR1, when Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the boiler.
Napomene za instalaciju
- Mains Switching Boiler
- Niski volumentage Switching Boiler
- Na TR2V2
- On the boiler PCB
- Na TR2V2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
Example 2 Two Two-way RF Switch:
- Programmer to Motorised Valve
- Motorised Valve to Boiler – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out contact closes, sending 230V to activate the boiler.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the motorised valve. When the valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

Napomene za instalaciju
1. Main Switching Boiler
2. Niska glasnoćatage Switching Boiler
3. Motorizirani ventil
- On the TRIV2
- On the boiler PCB
- On the TRIV2
- Na TR2V2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
- Link L to 3 to power the Live out terminal to the motorised valve.
Exampsamo 3 One way RF Switch:
Pump Overrun – Mains Switching
TR 1 v2
- On TRI, when Live in receives 230V from the boiler, TRI sends a wireless signal to TR2.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the pump.

Napomena o instalaciji
- Pumpa uključena
- the TR2V2
- Link L to 3 to power the Live out terminal to the pump
Exampsamo 4 Two Two-way RF Switch: Pump Overrun
- Programer za bojler
- Boiler to Pump – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out contact closes, sending 230V to activate the pump.
TR2V2
- On TR2, the COM & Live out contact closes, sending 230V to activate the boiler. When the boiler turns off, the pump overrun activates, sending 230V to the Live in contact. TR2 then sends a wireless signal to TRI.
Napomena o instalaciji
- Mains Switching Boiler
- Niski volumentage Switching Boiler
- Pumpa
- Na TR2V2
- On the boiler PCB –
- Na TR2V2
- On the TRIV2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
- Link L to 3 to power the Live out terminal to the pump.
Exampsamo 5 Two Two-way RF Switch: Unvented Cylinder:
- Programator za termostat visoke granice
- Motorised Valve to Boiler – Mains Switching
T RI v2
- On TRI
When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2. - On TRI
Live out the contact closes, sending 230V to activate the boiler.
TR2V2
On TR2, the COM & Live out contact closes, sending 230V to the high limit thermostat, powering the brown cable of the motorised valve. When the motorised valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.
Napomene za instalaciju
- Mains Switching Boiler
- Niski volumentage Switching Boiler
- Termostat visoke granice
- Motorizirani ventil
- On the TRIV2
- On the boiler PCB
- Na TR2V2
- Link L to 3.
- Remove the external controls link.
- Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
- Link L to 3 to power the Live out terminal to the High Limit thermostat.
EPH Kontrole IE
tehnički@ephcontrols.com
www.ephcontrols.com/contact-us
+353 21 471 8440
cork, Tl 2 W665
EPH Controls UK
technology@ephcontrols.co.uk
www.ephcontrols.co.uk/
kontaktirajte nas
+44 1933 322 072
Harrow, HAI IBD
FAQ
Q: Can I install the TR1, TR2V2V2 devices myself?
A: Installation should only be carried out by a qualified person following wiring regulations to ensure safety and proper functionality.
P: Koja je maksimalna udaljenost između TR1V2 i TR2V2 za učinkovitu komunikaciju?
A: The recommended distance is within 30 meters for optimal wireless signal transmission.
Dokumenti / Resursi
![]() |
EPH CONTROLS TR1V2-TR2V2 RF glavni prekidač [pdf] Upute za uporabu TR1V2, TR2V2, TR1V2-TR2V2 RF glavni prekidač, TR1V2-TR2V2, RF glavni prekidač, glavni prekidač, prekidač |